Efficiency + Physics

Accelerated Manual Systems

Products & Resources

Everything you need for a PHIBER Accelerated Manual System: complete kits, spec sheets, instructions, and accessories.

Accelerated Freshwater Maintenance poster: one dock hose feeding the PHLOW Hub and each connected system

Select Your Accelerated System

Cutaway of the PHLOW Hub splitting one hose into three engine lines

Sequencer Retrofit Kit

Replace a worn-out flush sequencer. Twin, Triple, and Quad.

Cutaway of a single hose run to one flush point

Solo Freshwater Maintenance System

Routine Freshwater Maintenance on any single application.

Hose running through the PHLOW Hub to multiple engines

Multi Freshwater Maintenance System

Routine Freshwater Maintenance on multiple applications simultaneously.

PHIBER PHLOW Hub and fittings on a dark surface

Simpliphy Your Phlush

Sequencer Retrofit Kit

Choose your size and finish at checkout.

Sizes: Twin, Triple, and Quad Engine (Quad up to 350 HP)

Flushing sequencers use a series of electric gates to direct fresh water through each engine, one at a time. But like all plastic, mechanical, and electrical devices exposed to the harsh marine elements, they eventually succumb to the wear and tear of boat life. When it’s time to replace yours, the Sequencer Retrofit Kit integrates into your existing flushing plumbing and swaps the sequencer for the PHIBER PHLOW Hub. Its oversized apertures and inner partitioning chamber protect water flow and pressure, flushing up to four engines at the same time with simple physics. Easy to install, zero maintenance.

Features

  • Marine grade construction (no “planned obsolescence”)
  • Elegant design with minimal installation footprint and complexity
  • Requires only “Physics” to operate: no electronics, electrical, or mechanical functions
  • Engineered for maximum water flow and minimum pressure loss
  • Replaces the valve sequencer between the dock hose connection and the engine freshwater flush plumbing

Kit Includes

  • PHLOW Hub
  • 1 1/4″ x 1″ reducer bushing for connecting to smaller network plumbing (dock hose)
  • PHIBER PHLOW Hub Overlay
  • Flush Placard
  • 3/4″ MPT Plug (Twin Engine kits)
Specs
Sequencer Retrofit Kit specifications
Hub Max Flow Rate50 GPM
Hub Max Pressure150 PSI
MaterialT6061 Aluminum Alloy, Clear Anodized
DimensionsOctagon, 5.5″ x 1.75″
Inlet1 1/4″ NPT
Outlets(3) 3/4″ NPT
Hub Materials CompatibilityPlastics, Stainless Steel
Finish OptionsClear Anodized (standard), Polished & Bright Anodized, White Powdercoat
StandardsCompliant to H23 Standards
Warranty2-year Materials & Labor
Stainless NPT-to-barb fittings and a Perko style dock hose inlet

Phlushing Convenience

Solo Freshwater Maintenance System

For smaller boats that can’t support a push-button PHIBER System but still need a routine freshwater flush for their engine, bait well, or other application at the end of the day. The Solo Kit allows for freshwater maintenance of a single application, with hose connection at a location that’s convenient to reach, eliminating hard-to-reach flush ports and the often-risky gymnastics of flushing an outboard if the vessel is stored on a lift or stays in the water. Oversized fittings deliver full flow to the engine during the flush.

Features

  • Marine grade construction (no “planned obsolescence”)
  • Minimal installation footprint and complexity
  • Allows flushing for single or twin engine configurations (additional fittings sold separately)
  • Compatible with other PHIBER Overboard Manifolds
  • Puts the freshwater flush hose connection in a convenient location

Kit Includes

  • Flush Placard
  • Perko Dock Hose Inlet
  • NPT-to-Barb fittings (stainless)
Specs
Single Engine Manual Flush Kit specifications
Dock Hose Inlet Type3/4″ standard garden/dock hose thread (GHT)
Dock Hose Inlet MountingBulkhead mount
System Max Flow Rate20 GPM
Max Pressure80 PSI
MaterialChromed Brass Hose Inlet, Stainless Fittings
DimensionsAssembled by installer
StandardsCompliant to H23 Standards
Warranty2-year Materials & Labor
PHLOW Hub installed in a boat with hoses connected

Phlushing with PHLOW

Multi Freshwater Maintenance System

Choose your size and finish at checkout.

Sizes: Twin, Triple, and Quad Circuit (Quad up to 350 HP)

Elegant and simple in both form and function, this Freshwater Maintenance System lets the full freshwater flow from a single dockside hose flush multiple engines at the same time. That means less water waste, less time and labor, and no more hooking a garden hose to each engine’s flush port. Its key feature is the patent-pending PHIBER PHLOW Hub. Born from high-performance fuel manifolds used on racing engines, it protects water flow using precision-machined oversize apertures and venturis. A proprietary partitioning chamber ensures flushing water divides smoothly and evenly, keeping GPM and pressure equal to every engine for a superior flush. It’s so effective it can often replace a less efficient valve-sequencing flush control, at a reduced cost!

Features

  • Requires only “Physics” to operate: no electronics, electrical, or mechanical functions (no “planned obsolescence”)
  • Elegant design with minimal installation footprint and complexity
  • Engineered for maximum water flow and minimum pressure loss
  • Eliminates the need for a complex valve sequencer
  • Single hose connection flushes up to four engines using direct “Hub-to-Head” plumbing through the engine’s rigging bundle

Kit Includes

  • PHLOW Hub (clear anodized)
  • 1 1/4″ x 1″ reducer bushing
  • PHIBER PHLOW Hub Overlay
  • Flush Placard
  • 3/4″ MPT Plug (Twin Engine kits)
  • Perko Dock Hose Inlet
  • NPT-to-Barb fittings (stainless)
Specs
Twin/Triple/Quad Engine Manual Flush Kit specifications
Dock Hose Inlet Type3/4″ standard garden/dock hose thread (GHT)
Dock Hose Inlet MountingBulkhead mount
System Max Flow Rate20 GPM
Max Pressure80 PSI
MaterialT6061 Aluminum Alloy Hub, Stainless Fittings
DimensionsHub: 5.5″ diameter x 1.75″ thickness
Hub Materials CompatibilityPlastics, Stainless Steel
Finish OptionsClear Anodized (standard), Polished & Bright Anodized, White Powdercoat
StandardsCompliant to H23 Standards
Warranty2-year Materials & Labor

Good to Know

  • A PHIBER System is comprised of Kits & Accessories that are chosen for a specific application, and integrated into a vessel’s existing systems and footprint.
  • Made in St. Augustine, Florida, USA.
  • Warranty: every PHIBER System includes a 2-YEAR warranty that covers the system, labor, materials, and even delivery to the boat.
  • Manual Systems are compatible with applications that have up to 1/2″ diameter native flush plumbing.
  • A proper flush needs 40 PSI minimum dock water pressure, a 1/2″ minimum diameter dock hose, and 2 GPM minimum flow for each engine.
  • Questions about your setup? Email sales@PHIBERSystems.com.